Search results for "Signal conditioning"
showing 6 items of 6 documents
Geoacoustic Inversion with Drifting Buoys: Enverse 1997–98 Experiments (Marettimo Is.)
2000
Acoustic buoys were developed to allow the rapid determination of range-dependent bottom properties in a shallow water environment from the inversion of propagation measurements. The main features of the buoys are the large dynamic range, digital signal conditioning unit, global positioning system receiver and reliable radio data link. The buoys drift away from a broadband source receiving its pings at known positions. Single hydrophone, matched waveform, inversion techniques are applied to the received signals to invert for geoacoustic parameters. Eight prototypes were tested over the southern continental shelf off the island of Marettimo (Sicily) during the EnVerse 97 sea trials. Calibrat…
Improving bleeding detector features for electron intraoperative radiotherapy
2019
Abstract Purpose The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. Methods Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been develope…
Dynamic Light Scattering Signal Conditioning for Data Processing
2017
Abstract When performing data acquisition for a Dynamic Light Scattering experiment, one of the most important aspect is the filtering and conditioning of the electrical signal. The signal is amplified first and then fed as input for the analog digital convertor. As a result a digital time series is obtained. The frequency spectrum is computed by the logical unit offering the basis for further Dynamic Light Scattering analysis methods. This paper presents a simple setup that can accomplish the signal conditioning and conversion to a digital time series.
Coulomb blockade thermometer: Tests and instrumentation
1998
Coulomb blockade thermometry (CBT) provides a simple method for absolute thermometry in every day laboratory use at cryogenic temperatures. CBT has been found insensitive to even high magnetic fields. We review the principles and the operation of CBT and the fabrication of the sensors, and present new data on radiation hardness and stability of the sensors. We describe the instrumentation of CBT in detail. We have developed two signal conditioning units for CBT measurements. One is a modified alternating current resistance bridge, a versatile laboratory instrument operating with a PC computer, and the other one is a simple stand-alone instrument for direct temperature reading. Test results …
A microcomputer system for controlling classical conditioning experiments
1994
A microcomputer-based laboratory system for controlling stimulus presentations and data acquisition in classical conditioning experiments is described. The system comprises an Intel 386/486-based microcomputer and a commercially obtained low-cost counter/timer board with input/output lines for stimulus timing and external device control. A simple, yet versatile custom-designed structured programming language is provided for performing an unlimited number of stimulus configurations and their sequences. In electrophysiological studies, the system can be flexibly connected to computer-controlled signal conditioning systems for the amplification and filtering of multiunit and evoked field poten…
Real Time Assessment of Potable Water Quality in Distribution Network based on Low Cost Multi-Sensor Array
2018
New concepts and techniques are replacing traditional methods of water quality parameters measurement systems. This paper proposed a new way of potable water quality assessment in distribution network using Multi Sensor Array (MSA). Extensive research suggests that following parameters i.e. pH, Dissolved Oxygen (D.O.), Conductivity, Oxygen Reduction Potential (ORP), Temperature and Salinity are most suitable to detect overall quality of potable water. Commonly MSA is not an integrated sensor array on some substrate, but rather comprises a set of individual sensors measuring simultaneously different water parameters all together. Based on research, a MSA has been developed followed by signal…